Handhled Touch Screen OTDR Fiber Optics Equipment (made in China, Certified) by Hangzhou Techwin Precision Instrument Co., Ltd
- Item Condition:
- Brand:
- Model#:
- Location:
- Price:
| Hangzhou Techwin Precision Instrument Co., Ltd | |
86-571-88284299
|
|
Contact the seller Add to Inquiry Cart
Product Description
The Parameters
Wavelength(nm) | 850/1300 | 1310/1550 | 1310/1490/1650 | 1625 | ||||||||
Dynasmic range(dB)2 | 23/21 | 32/30 | 34/32 | 36/34 | 38/36 | 34/32/32 | 38/36/36 | 304 | 325 | 344 | 365 | |
Pluse width(ns) | 5,20,40,80,160, 320,640,1280 | 5,20,40,80,160,320,640,1280,2560,5120,10240,20480 | ||||||||||
Event blind zone(m)3 | 2m | 2m | ||||||||||
Attenuation blind zone(m)3 | 9m | 9m | ||||||||||
Linearity(dB/dB) | ±0.05 dB/dB | |||||||||||
Loss threshold Loss resolution ratio(m) Sampling resolution ratio(m) Sampling point Distance uncertainty(m) | 0.05 | |||||||||||
0.01 | ||||||||||||
0.125 to 8 | ||||||||||||
32K | ||||||||||||
±(1m + 5*10-5* distance + sampling interval) | ||||||||||||
Distance scope(km) | 0.3 to 180 | |||||||||||
Typical real-time refreshing duration(s) | 0.2 | |||||||||||
Display | 5.6 inch Color TFT LCD | |||||||||||
Memory capacity of trace | SD Card(2G), >10000 pieces | |||||||||||
Optical Interface | FC/UPC(PO & APC are selectable) | |||||||||||
Data interface | USB interface, SD card interface | |||||||||||
VFL | 650nm, ≥-3 dBm | |||||||||||
Operating temperature | -10°C~50°C | |||||||||||
Storage temperature | -40°C~70°C | |||||||||||
Power supply | Lithium battery; continuing working duration ≥ 8 hours | |||||||||||
Dimensions (H*W*D) | 150*235*66 | |||||||||||
Weight (kg) | 1.5 | |||||||||||
Remarks: 1. The technical specification describes the ensured performance of the instrument when using typical PC model connector to measure. Without considering the uncertainty caused by optical fiber refractivity.
2. Dynamic range is the data measured under the condition of the maximum pulse width and 3 minutes of average time. Dynamic range is the data measured under the condition of 180km/20480ns/3min.
3. Measuring conditions of blind zone: reflection event is within 4Km, reflection strength < -35dB. Measured by the minimum pulse width.
4. Dynamic range measured when there is filter.