Sorry, the search criteria can not be empty
Search

128*64 Dot Matrix Graphic Power Quality Analyzer AFLEX-6300 by Shenzhen Youfu Tools Co., Ltd

  • Item Condition:
  • Brand:
  • Model#:
  • Location:
  • Price:
Shenzhen Youfu Tools Co., Ltd
86-755-83258692


Contact the seller Add to Inquiry Cart

Product Description

Specifications

1.Programmable PT (1 to 3000) Ratios
2.Large Dot Matrix LCD Display with Backlight
3.Built-in Calendar Clock for Data Logging

Feature:

Display of Overlapped Voltage and Current Waveform
•Maximum Demand (MD in W, KW, MW) with Programmable Period
•Harmonics Analysis ( V and I ) to the 50th Order
•Display of 25 Harmonics in One Screen with Waveform
•Display of waveform with Peak Values (512 Samples / Period), Datalogging of 32, 64, 128 or 256 Points/Cycles
•Analysis of Total Harmonics Distortion ( % THD-F )
•Graphic Phasor Diagram
•Capture 128 Transient Events ( Time + Cycles + Faults ) with Programmable Threshold(%), Can Also be Reviewed in LCD
•50000 Records with Programmable Interval ( 1 to 6000 seconds)
•Output of Waveform, Power Parameters and 50 Harmonics at Command.
•Optical Isolated RS-232C Interface
•Smart Datalogging to save Battery Power for Long-term Monitoring

Specification:

AC Watt ( 45 ~ 65 Hz, PF 0.5 to 1, CT=1 )

Range
Resolution
Accuracy of Readings
100.0 - 999.9 W
0.1 W
2% ± 8 dgts
1.000 - 9.999 KW
0.001 KW
2% ± 8 dgts
10.00 - 99.99 KW
0.01 KW
2% ± 8 dgts
100.0 - 999.9 KW
0.1 KW
2% ± 8 dgts
1000 - 9999KW
1 KW
2% ± 8 dgts

AC Current (45~65 Hz , True RMS)

Range
Range
Resolution
Accuracy of Readings
30 - 300 A
0.00 - 300 A
0.1 A
1 % of range ± 8 dgts
300 - 999.9 A
100.0 - 999.9 A
0.1 A
1 % of range ± 8 dgts
1000 - 3000 A
1000 - 3000 A
1 A
1 % of range ± 8 dgts

Harmonics of ACA in % and Magnitude (1 to 50th order)

Range
Resolution
Accuracy in %
Resolution
Accuracy in Magnitude
10.0 - 300 A
0.1 %
±1.0%
0.1 A
±1.0% of range ± 0.8A
1000 - 3000 A
0.1 %
±1.0%
1 A
±1.0% of range ± 3 A

Power Factor (PF)

Range
Resolution
Accuracy of Readings
0.00 - 1.00
0.01
± 1.5 % ± 8 digits

Harmonics of AC Voltage in % and Magnitude (1 to 50th order)

Range
Resolution
Accuracy in %
Resolution
Accuracy in Magnitude
50 - 600 V
0.1 %
±0.5%
0.1V
±0.5 % ± 0.5V

Phase Angle ( Φ )

Range
Resolution
Accuracy of Readings
-180 ° to 180 ° (0 ° to 360 ° )
0.1 °
± 1 % ± 2 digits

AC Voltage ( 45 ~ 65 Hz, True RMS)

Range
Resolution
Accuracy of Readings
3 V - 600 V
0.1 V
± 0.5 % ± 5 dgts

Total Harmonics Distortion (% THD-F , 1 to 50th order)

Range
Resolution
Accuracy of Readings
0.0 - 999.9 %
0.1 %
± 0.5 % ± 5 digits

General Specification:

Conductor Size150 mm (approx.)
Battery Type1.5 V SUM-3 *2
Display128*64 Dot Matrix
Power Consumption

10 mA (approx.)

Auto - Power - Off15 minutes
LCD update rate2 times/sec
Dimension130mm(L)*80mm(W)*43mm(H), 5.1"(L)*3.1"(W)*1.7"(H)
AccessoriesTest lead*1 pair, Users manual*1, Batteries 1.5V*2
No. of Sample / Period512 ( V & A ), 256 (W)
Operating Temperature-10 °C to 50 °C
Operating Humidity< 85% RH
Storage Temperature-20 °C to 60 °C
Storage Humidity< 75 % RH
Weight450g


Item added to Inquiry Cart

Continue shopping Go to Inquiry Cart