Sorry, the search criteria can not be empty
Search

Agilent/HP E4350B Solar Array Simulator by US Instrument

  • Item Condition:
  • Brand:
  • Model#:
  • Location:
  • Price:
US Instrument
800-870-0787


Contact the seller Add to Inquiry Cart

Product Description

Agilent/HP E4350B Solar Array Simulator

 

Agilent/HP E4350B Solar Array Simulator

Rent me for $700 a month

with option

  • J04 43.5 Volt 11 Amp 480 Watt Output

   The Agilent/HP E4350B one-box Solar Array Simulator (SAS) is a DC power source that simulates the output characteristics of a solar array. The SAS is primarily a current source with very low output capacitance and is capable of simulating the I-V curve of different arrays under different conditions (i.e., temperature, age etc.). The I-V curve is programmable over the IEEE-488.2 bus and is conveniently generated within the SAS. The SAS provides three current operating modes:

1. Simulator Mode: An internal algorithm is used to approximate a SAS I-V curve. Four input parameters: Voc (open circuit voltage), Isc (short circuit current), Imp and Vmp (current and voltage at the peak power point on the curve) are needed to establish a curve in this mode.

2. Table Mode: For a fast and accurate I-V simulation, the SAS provides a table mode. The I-V curve is set by a user-defined table of points. A table can have any length up to 4000 points (a point corresponds to a specific value of I and V). As many as 30 tables may be stored in each of the SAS built-in volatile and non-volatile memory. Non-volatile memory can store a maximum of 3500 points. The tables (I-V curves) are easily stored and recalled with an IEEE-488.2 command. The table(s) stored in this memory will be retained when the power is turned off. Volatile memory greatly increases the flexibility by saving up to 30,000 points. Multiple tables are easily accessed with IEEE-488.2 command. These tables will be erased after power is removed. In Table Mode, current and voltage offsets can be applied to the selected table to simulate a change in the operating conditions of the solar array.

3. Fixed Mode: This is the default mode when the unit is powered on. The unit has the rectangular I-V characteristics of a standard power supply, when an output capacitor is added in this mode.

Features

  • 480 Watt output
  • Auto-parallel capability for higher power
  • Very low output capacitance
  • Switching recovery time in less than 5 microseconds
  • Programmable overvoltage and over-current protection which are independent of other circuits
  • Over temperature protection
  • Fan speed control to minimize acoustic noise
  • Extensive set of programming features
  • Fast I-V curve change in both table and simulator modes
  • Up to 60 volatile/non-volatile tables
  • Self test at power-up or from an IEEE-488.2 command
  • Serial link to connect up to 16 outputs to one IEEE-488.2 address
  • Standard Commands for Programmable Instruments (SCPI)

Item added to Inquiry Cart