New Atten Instruments AT7340 40 MHz 2 Channel Oscilloscope
The Atten Instruments AT7340 offers excellent value for the price. It is a well built and reliable oscilloscope. Maximum sensitivity is 5mV/div, maximum sweep speed is 0.2 us/div, and can be expanded ten times to 20ns/div. The display is a large 6 inches with a red graticule rectangular CRT
Features
- CRT with Bright and high accelerated pole voltage This oscilloscope tube is high speed and high luminosity.
- The alternative triggering function can observe different signal waveform in two frequencies.
- TV signal synchronous function built in
- CH1 output 50 output signal in the rear panel can drive frequency counters directly or other instruments.
- Z-axial input Function of bright adjustable can add frequency or time marker to oscilloscope, trace of positive signal blanking, TTL matching
- X-Y operation This item can be used as an X-Y oscilloscope while setting in X-Y position, CH1 is horizontal axial and CH2 is vertical axial.
Vertical Axis
- Sensitivity 5mV~5V/DIV, 10 steps in 1-2-5 sequence (X5 MAG: 1mV/DIV)
- Sensitivity accuracy ≤3% (Ã5MAG: ≤5%)
- Vernier vertical sensitivity continuously variable to 1/2.5 or less of panel-indicated value
- Frequency bandwidth DC-20MHz (Ã5MAG:DC-7MHz) / DC-40MHz (Ã5MAG:DC-15MHz)
- AC coupling Low limit frequency 10Hz. (With reference to 100KHz, 8DIV.Frequency response with-3dB)
- Rise time Approx.17.5Ns (Ã5MAG:Approx.50Ns) / 9.5nS (X5MAG: Approx.25nS)
- Input impedance Approx. 1M ohm//Approx. 25pF
- Square wave characteristics Overshoot: ≤5%(At 10Mv/DIV range) other distortions and other ranges: 5% added to the above value
- DC balance shift: 5mV~5V/DIV; ±0.5 DIV, 1mV~2mV/DIV±2.0DIV
- Linearity: ±0.1DIV of amplitude change when waveform of 2 DIV at graticule center is moved vertically.
- Vertical modes CH1 single channel. / CH2 single channel
- DUAL CH1 and CH2 are displayed ALT or CHOP selectable at any sweep rate.
- ADD CH1+CH2 algebraic addition
- Chopping repetition frequency Approx.250KHz
- Input coupling AC, GND , DC
Maximum Input Voltage
- 300V peak (AC: frequency 1KHz or lower) When set probe switch at 1:1, the maximum effective readout is 40Vp p (14Vrms at sine wave); or set probe switch at 10:1, the maximum effective readout is 400Vpp (140Vrms at sine wave)
Horizontal Axis
- Sweep time 0.2ìSec-0.5Sec/DIV, 20Steps in 1-2-5sequence
- Sweep time accuracy ±3%
- Vernier sweep time control ≤1/2.5 of panel-indicated value
- Sweep magnification 10 times
- Ã10MAG sweep time accuracy ±5%(20nsec-50nsec are uncalibrated)
- Linearity ±3%,Ã10MAG: ±5%(20ns and 50ns are uncalibrated)
- Position shift caused byÃ10MAG Within 2 DIV, at CRT screen center