The Fluke 5502A Multi-Product Calibrator addresses common workload items like 3.5 and 4.5 digit digital multimeters and more. It comes with internal and external protection features that enable you to transport it easily and perform onsite or mobile calibration. The 5502A can also be fully automated with MET/CAL® Plus Calibration Management Software. It is the ideal calibrator for metrology professionals who need a solution for calibrating low-to-medium accuracy electrical instrumentation.
The Fluke 5502A Calibrator sources direct voltage and current, alternating voltage and current with multiple waveforms and harmonics, simultaneous voltage outputs or dual voltage and current to simulate dc and ac power with phase control, resistance, capacitance, thermocouples and RTDs. The 5502A can also measure thermocouples and thermocouple simulators. Two options add the capability to calibrate oscilloscopes to either 300 MHz or 600 MHz. Additionally, with the 52120A Transconductance Amplifier and current coils, the 5502A can calibrate instruments at up to 6000A.
Features of the Fluke 5502A include:
Calibrates a wide variety of electrical test equipment
Robust protection circuits prevent costly damage from operator error
Ergonomically designed carrying handles make the 5502A easy to transport
Rugged carrying case with built-in handles and wheels and removable front/rear access doors for in-situ calibration in almost any environment
Current output that extends to 120 A when paired with the 52120A Transconductance Amplifier
Specifications of the Fluke 5502A include:
Direct volts: 0 to ± 1020 V
Direct current: 0 to 20.5 A
Alternating volts: 1 mV to 1020 V / 10 Hz to 500 kHz
Volt*Hertz: 1000 V@ 10 kHz/330 V@100 kHz
Alternating current: 29 μA to 20.5 A / 10 Hz to 30 kHz
Waveforms: Sine, square, triangle, truncated sine
Resistance: 0 Ω to 1100 MΩ
Capacitance: 220 pF to 110 mF
Power (phantom loads): 20.9 kW
Phase control: 0.01°
Thermocouple (source and measure temperature): B, C, E, J, K L N R, S, T, U / 10 μV/°C and 1 mV/degC
RTD (source temperature): Pt 385-100 Ω, Pt 3926-100 Ω Pt 3916-100 Ω, Pt 385-200 Ω, Pt 385-500 Ω, Pt385 1000 Ω, PtNi 385-120 Ω, (Ni120), Cu 427 10 Ω
Interfaces: RS-232, IEEE 488
Frequency uncertainty: <25 ppm
Oscilloscope calibrator (optional): Levelled sine wave from 5 mV to 5.5 Vpp max, frequencies 50 kHz to 600 kHzz; edge rise times of < 300ps, multiple trigger functions, lowest dc, square wave and timing uncertainty
Current boost transconductance amplifier: 0 to 100 A dc, 0 to 120 A ac, dc to 10 kHz, up to 6000 A with accessory current coils