The Fluke 2625A Hydra Data Logger is differentiated by its built-in non-volatile recording capability. This feature makes data capture and offline storage very flexible and convenient. The memory holds 2047 sets of readings on each of the 21 analog input, 12 digital I/O, and totalizer channels - enough to hold one scan per minute for more than 24 hours. The Hydra Data Logger is ideal for recording data during environmental stress screening, thermal testing, design testing, and other applications that require data logger with up to twenty analog measurement channels.
Features of the Fluke 2625A DataLogger include:
Channel Scanning: can be continuous scanning, scanning at an interval time, single scans, or triggered (internal or external) scans
Channel Monitoring: make measurements on a single channel and view these measurements on the display
Channel Scanning and Monitoring: view measurements made for the monitor channel while scanning of all active channels continues
Multi-Function Display: Left (numeric) display shows measurement readings; also used when setting numeric parameters; Right (alphanumeric) display used for numeric entries, channel number selection and display, status information, and operator prompts
Front-Panel Operation
Measurement Input Function and Range:
Volts dc (Vdc), dc voltage ranges 300 mV, 3 V, 30 V, 300 V
Volts ac (Vac), ac voltage ranges 300 mV, 3 V, 30 V, 300 V
Frequency (Hz), 15 Hz to 1 MHz
Resistance (O), resistance ranges: 300 O, 3 kO, 30 kO, 300 kO, 3 MO, 10 MOTemperature Measurement: Thermocouple types J, K, E, T, N, R, S, and B, and Hoskins Engineering Co. type C are supported. Also, DIN/IEC 751 Platinum RTDs are supported
Totalize Events on the Totalizing Input
Alarm Limits and Digital Output Alarm Indication
4-Terminal Resistance Measurements (Channels 1 through 10 only)
RS-232 Computer Interface Operation
Measurement Rate Selection
Nonvolatile Memory: Storage of minimum, maximum, and most recent measurements for all scanned channels. Storage of Computer Interface setup, channel configurations, and calibration values. Storage of measurement data: storage for 2047 scans of up to 21 channels, representing up to 42,987 readings
RS-232 interface
90 to 264 Vac, 50 or 60 Hz operation; or 9.0 to 16 Vdc
Weight: 7 lb; Size: 93 mm (3.67 in)H x 216 mm (8.5 in)W x 312 mm (12.3 in)D