When the Agilent 81104A Pulse Pattern Generator Mainframe is combined with one or two Agilent 81105A output modules (single and/or dual channel) builds on the performance of the 81101A and is also backward-compatible. Each Agilent 81104A single-channel Pulse Pattern Generator requires one Agilent 81105A output module. For the dual-channel configuration, two Agilent 81105A output modules are required. If two Agilent 81105A Output modules are available, the outputs can be added. This allows elaborate pulse shapes for simulating glitches, testing clock-recovery circuits or generating 3- or 4-level codes.
The Agilent 81104A produces all the standard pulses and digital patterns needed to test current logic technologies. By using the internal channel addition feature provided by the optional second channel, multi-level and multi-timing signals can be produced. The Agilent 81104A Pulse Pattern Generator provides high quality signals and flexibility that meet virtually all application needs.
Features and Specifications of the Agilent 81104A Pulse Pattern Generator include:
Features:
Single-/dual-channel pulse pattern generator mainframe
Extends the frequency range and adds RZ/NRZ pattern capability up to 16 kbit per channel
An NRZ strobe channel provides:
a trigger at arbitrary points in the pattern
or can be used as an additional pattern source
Triggerable / PLL operation selectable
Pulse / burst / pattern modes selectable
Variable transition times
BNC outputs: single-ended
Dropout and glitch free timing change
Channel-add and 1000 Ohm source modes:
Each operate up to about 60 MHz
Combined, the maximum speed is about 15 MHz.
Clean, accurate pulses with excellent repeatability providing reliable measurements
Features such as the clear graphical display, autoset, help, store / recall, preset TTL / ECL levels, selectable units (such as current / voltage, width / duty-cycle), and load compensation ensure a high level of convenience that make it easy to use
Internal channel addition:
Provides multi-level and multi-timing signals to be obtained
Variable pulse parameters in pattern mode as well as in pulse mode
Synchronously triggerable
Simulation of reflections / distortions
Three / four-level codes
Flexible pulses or patterns for digital designs:
Pattern mode including pseudo-random binary sequence
Outputs of dual-channel instruments can be added (analog or EXOR, depending on model)
User-retrofittable channels
Upward compatibility
Individual solutions for frequencies up to 50, 80, 165, 330, 400, and 660 MHz
100% form / fit compatibility
Specifications:
Mainframe: 81104A
Channel Model: 81105A, 80 MHz, 10 V
# of channels: 1 or 2
Single or dual-channel: Requires 1 or 2 output Agilent 81105A modules
Frequency Range: 1 MHz - 80 MHz
Variable delay range: 12.5 ns - 999.5 s
Period RMS - jitter: 0.00 s - 999.5 s
Width Range: 6.25 ns - 9.995 s
Amplitude Range: 100 mV - 20.0 V (Depends on selected impedance (all other values for 50 Ω source impedance into 50 Ω load))
Transition Time Range (10/90): 3.00 ns - 200 ms
Source Impedance: 50 Ω or 1 kΩ