Sorry, the search criteria can not be empty
Search

STANFORD RESEARCH DS360 ULTRA-LOW DISTORTION FUNCTION GENERATOR, 1 MHZ - 200 KHZ by Axiom Test Equipment

  • Item Condition:
  • Brand:
  • Model#:
  • Location:
  • Price:
Axiom Test Equipment
(760) 806-6600


Contact the seller Add to Inquiry Cart

Product Description

The Stanford Research Systems (SRS) DS360 Ultra-Low Distortion Function Generator offers the performance of a low distortion analog source combined with the precision of direct digital synthesis (DDS) making it the ideal source for audio frequency applications.

Unlike conventional RC oscillators, the SRS DS360 Ultra-Low Distortion Function Generator uses digital signal processing and a precision 20-bit D/A converter to provide ultra low distortion over the audio frequency range. With its DDS architecture the SRS DS360 Generator has the features and flexibility of a contemporary synthesized function generator. Careful shielding and board layout keep the output noise to a minimum, making the SRS DS360 Generator the instrument of choice for audio research and development, manufacturing, and automated testing.

The SRS DS360 Generator is designed for bench-top use as well as automated testing. All functions and parameters are easily set using the front-panel keypad and spin knob. A wide variety of amplitude units can be selected. Front-panel outputs and dual banana jacks assure compatibility with any system. The SRS DS360 Generator is fully computer programmable, which is a feature seldom found in low-distortion sources. All instrument functions can be controlled or queried through the computer interfaces.

Features and Specifications of the SRS DS360 Ultra-Low Distortion Function Generator include:
  • 10 mHz to 200 kHz frequency range

  • <-100 dBc distortion (to 20 kHz)

  • Sine, square, white and pink noise

  • 20 µVpp to 40 Vpp output range

  • Linear and log frequency sweeps

  • 25 ppm frequency accuracy

  • Balanced and unbalanced outputs

  • RS-232 and GPIB interface

  • Waveforms:

    • Sine:  

      • Frequency Range:  0.01 Hz to 200.000 kHz

    • Square:

      • Frequency Range:  0.01 Hz to 200 kHz

      • Rise Time:  1.3 µs

      • Even Harmonics:  < -60 dBc (to 20 kHz)

    • White Noise:

      • Bandwidth:  DC to 200 kHz

      • Flatness:  <1.0 dB, 1 Hz to 100 kHz

      • Crest Factor:  11 dB

    • Pink Noise:

      • Bandwidth:  10 Hz to 200 kHz

      • Flatness:  < 3.0 dB, 20 Hz to 20 kHz (measured using 1/3 octave analysis)

      • Crest Factor:  12 dB

    • Bandwidth Limited Noise:

      • Bandwidth:  100 Hz, 200 Hz, 400 Hz, 800 Hz, 1.6 kHz, 3.2 kHz, 6.4 kHz, 12.8 kHz, 25.6 kHz, 51.2 kHz, 102.4 kHz

      • Center Frequency:  0 Hz to 200.0 kHz (200 Hz increments)

      • Flatness (in band):  <1.0 dB

      • Crest Factor:

        • Baseband:  12 dB (0 Hz center frequency)

        • Non-Baseband:  15 dB

    • Two-Tone:

      • Type:  Sine-sine, sine-square

      • Sine Frequency:  0.01 Hz to 200 kHz

      • Square Frequency:  0.1 Hz to 5 kHz

      • Square Resolution:  2 digits

      • SFDR:  >90 dB

    • Sine or Square Burst:

      • On Cycles:  1/2, 1 to 65534 cycles

      • Repetition Rate:  1 to 65535 cycles

      • Triggering:  Internal, external, single-shot, externally gated

      • Off Level:  0.0 % to 100.0 % (of on level)

      • Off Resolution:  0.1 %

      • Max Off Attenuation:  

        • -90 dBc (1 kHz)

        • -70 dBc (10 kHz)

        • -50 dBc (100 kHz)

    • White or Pink Noise Burst:

      • On time:  10 µs to 599.9 s        

      • Repetition Time:  20 µs to 600 s

      • Triggering:  Internal, external, single-shot, externally gated

      • Off Level:  0.0 % to 100.0 % (of on level)

      • Resolution:  0.1 %

    • Sine or Square Sweep:

      • Type:  Linear or logarithmic

      • Range:  0.01 Hz to 200.000 kHz

      • Rate:  0.1 Hz to 3.1 kHz

      • Resolution:  2 digits

      • Flatness:  Â±0.1 dB (1 %)

  • Frequency:

    • Resolution:  6 digits or 10 mHz (whichever is greater)

    • Accuracy:  25 ppm (0.0025 %) + 4 mHz (20 °C to 40 °C)

  • Amplitude:

    • Unbalanced Outputs:

      • 5.0 µVpp to 14.4 Vpp (50 O load)

      • 5.0 µVpp to 20.0 Vpp (600 O load)

      • 10.0 µVpp to 40.0 Vpp (Hi-Z load)

    • Balanced Outputs:

      • 10 µVpp to 28.8 Vpp (50 O load)

    • 10 µVpp to 28.8 Vpp (150 O load)

    • 10 µVpp to 40.0 Vpp (600 O load)

    • 20 µVpp to 80.0 Vpp (Hi-Z load)

    • Resolution:  4 digits or 1 µV, whichever is greater (Vpp or Vrms), 0.1 dB (dBm or dBV)

    • Accuracy:  Â±0.1 dB (1 %)

  • Noise (Broadband):

    • <4 nV/vHz (<12.6 mVpp)

    • <7.5 nV/vHz (12.6 mVpp to 126 mVpp)

    • <15 nV/vHz (126 mVpp to 1.26 Vpp)

    • <150 nV/vHz (1.26 Vpp to 40 Vpp)

    • (for a 1 kHz sine wave into Hi-Z load)

  • Offset:

    • Unbalanced Output:

      • 0 to ±7.4 VDC (50 O load)

      • 0 to ±10.0 VDC (600 O load)

      • 0 to ±20.0 VDC (Hi-Z load)

    • Balanced Output:  Not active

    • Resolution:  3 digits

    • Accuracy (all except pink noise):

      • 1 % ± 25 mV (Vp+offset > 0.63 V)

      • 1 % ± 2.5 mV (0.63 V > Vp+offset > 0.063 V)

      • 1 % ± 250 µV (63 mV > Vp+offset > 6.3 mV)

      • 1 % ± 50 µV (Vp+offset < 6.3 mV)

    • Accuracy (pink noise):

      • 1 % ± 200 mV (Vp+offset > 0.63 V)

      • 1 % ± 20 mV (0.63 V > Vp+offset > 0.063 V)

      • 1 % ± 2 mV (63 mV > Vp+offset > 6.3 mV)

    • 1 % ± 200 µV (Vp+offset < 6.3 mV)

  • Outputs:

    • Configuration:  Balanced and unbalanced

    • Connectors:  Floating BNCs, banana plugs and XLR jack

    • Source Impedance:  

      • Balanced:

        • 50 O ± 3 %

        • 150 O± 2 %

        • 600 O ± 1 %

        • Hi-Z (50 O ± 3 %)

      • Unbalanced:  

        • 50 O ± 3 %

        • 600 O ± 1 %

        • Hi-Z (25 O ± 1 O)

    • Floating Voltage:  Â±40 VDC (max)

  • Other Outputs:

    • Sync:  TTL level (same frequency and phase as output)

    • Burst Out:  TTL pulse marks burst (TTL high for ON time)

    • Trigger/Gate In: TTL pulse starts sweep or burst TTL high activates gated burst

    • Sweep:  TTL pulse marks beginning of sweep

  • General:

    • Computer Interfaces:  GPIB and RS-232. All instrument functions can be controlled.

    • Power:  50 W, 100/120/220/240 VAC, 50/60 Hz


Item added to Inquiry Cart