The Fluke 2638A, with its superior DC measurement accuracy, industry-leading thermocouple accuracy, full-color display, easy-to-use menu system, and industrial safety ratings, adds a new dimension to how data is collected and viewed in a portable system, and also puts the Fluke 2638A in a category all its own.
Features and Specifications of the Fluke 2638A Data Acquisition System / Digital Multimeter include:
Features:
DC accuracy of 0.0024%
Thermocouple accuracy of 0.5 °C
Up to 66 universal differential isolated inputs
On-screen color trend graphing of up to four channels at a time
Easy-to-use menu system for setup and data management
Input types: ac V, dc V, ac I, dc I, thermocouple, PRT (2,3,4 w), thermistor, resistance (2-4 w), frequency
Multi-channel real-time data display
6.5-digit bench DMM function for front-panel inputs
Monitor function for real-time viewing and charting between scans
20 on-board math channels
One-button screen capture of chart or data displays
45 channels/second basic dc scan rate
Internal 57,000 scan/setup file memory
USB flash drive support
Data security features
300 V CAT ll input safety rated
Specifications:
Technical Specifications:
DC Volts:
Range: 100 MV to 300 V
Resolution: 0.1 µV to 1 mV
Accuracy: 0.0024%
AC Volts:
Range: 100 MV to 300 V
Resolution: 0.1 µV to 1 mV
Accuracy: 0.11%
Resistance:
Range: 100 Ω to 100 MΩ
Resolution: 0.1 mΩ to 100 Ω
Accuracy: 0.01%
Frequency:
Range: 20 Hz to 1 MHz
Accuracy: 0.01%
RTD (Pt 100):
Range: -200 ºC
Resolution: 0.001 ºC
Accuracy: 0.016 ºC
J Thermocouples:
Range: -200 ºC to 1,000 ºC
Resolution: 0.01 ºC
Accuracy: 0.53 ºC
K Thermocouples:
Range: -200 ºC to 1,000 ºC
Resolution: 0.01 ºC
Accuracy: 0.60 ºC
Accuracy: 0.016 ºC
T Thermocouples:
Range: XXXXXXXXXX
Resolution: 0.01 ºC
Accuracy: 0.62 ºC
Other Thermocouple types: R, S, N, E, B, C, D, G, L, M, U, W
General Specifications:
Channel Capacity:
Analog inputs:
22 to 66 channels
8 Digital I/O
6 Alarm Outputs (TTL)
Totalizer: 1
Power:
Voltage: 100V to 264A in 4 power model selections (100V, 120V, 220V, 240V)
Frequency: 47Hz to 440Hz (automatically sensed when turned on)
Power consumption: 34VApeak (24W average)
Communication:
LAN: 10/100 Mb TCPIP DHCP
Remote commands: SCPI command set
Internal memory:
57,000 scans
1000 setup files
File security:
Dual level, Administrator, five secure users, Guest status
Alarm outputs: 6 TTL alarm outputs - assignable to one or multiple channels
Alarm setpoints: 2 assignable setpoints/channel, Hi Lo, Hi Hi, Lo Lo