Sorry, the search criteria can not be empty
Search

KEITHLEY 2601 SOURCEMETER, 3A DC, 40W, 1 CH. by Axiom Test Equipment

  • Item Condition:
  • Brand:
  • Model#:
  • Location:
  • Price:
Axiom Test Equipment
(760) 806-6600


Contact the seller Add to Inquiry Cart

Product Description

The Keithley 2601 SourceMeter lets you make precision DC, pulse, and low frequency AC source-measure tests faster, easier, and more economically than before. The Keithley 2601 offers two to four times the test speed of competitive products for I-V functional testing by combining:

  • Keithley’s high speed, third-generation Source-Measure Unit (SMU) design

  • An embedded Test Script Processor (TSP™)

  • TSP-Link™, a fast triggering and inter-unit communication bus

The Keithley 2601 has a single 40W, 3A channel and is electrically isolated to ensure high measurement integrity and wiring flexibility. The Keithley 2601 packs many instruments into a small package, including:
  • Aprecision power supply

  • A true current source

  • A 51/2-digit multimeter

  • A voltage or current pulse generator with measurement

  • A low frequency arbitrary waveform generator

  • An electronic load

  • A trigger controller

Features and Specifications of the Keithley 2601 include:
  • TSP-Link allows connection of multiple 2600 series instruments in a master/slave config allowing unlimited scalability

  • On-board Test Script Processor processes and runs complex sequences from the instrument - gives you up to 10X greater throughput

    • allows creation of custom measurement functions for components such as varistors, diodes and BJTs/FETs, or algorithm based tests like I-V sweeps with power compliance, linearity and latch-up test sequences, and thermal response tests.


  • Store up to 50,000 lines of TSP code and more than 200,000 readings in 16MB of nonvolatile memory.

  • Measure I and V at >10,000 readings/s. Execute a full source-measure cycle in just 200µs

  • Ensure repeatable timing and high throughput with the high speed auto-ranging function.

  • GPIB, RS-232 and 14-bit digital I/O interface ports are standard

  • Current measure range (per channel) 1pA to 3A

  • Current source range (per channel) 5pA to 3A

  • Basic current programming accuracy 0.03%

  • Basic current measurement accuracy 0.02%

  • Voltage measure range (per channel) 1µV to 40V

  • Voltage source range (per channel) 5µV to 40V

  • Basic voltage programming accuracy 0.02%

  • Basic voltage measurement accuracy 0.015%

  • Readings to memory 10,000/s

  • Sweep source change and reading to memory 5,500/s

  • Sweep source change and reading to GPIB 3,600/s

  • Spot readings to GPIB 1,100/s

  • Spot source change and reading to GPIB 880/s

  • Pulse capability 200µs minimum source/measure pulse