The Tektronix RSA6114A Realtime Spectrum Analyzer will help you to easily discover design issues that other signal analyzers may miss. The revolutionary DPX spectrum display offers an intuitive live color view of signal transients changing over time in the frequency domain, giving you immediate confidence in the stability of your design, or instantly displaying a fault when it occurs. This live display of transients is impossible with other signal analyzers. Once a problem is discovered with DPX, the RSA6114A Real-time Spectrum Analyzer (RTSA) can be set to trigger on the event, capture a continuous time record of changing RF events and perform timecorrelated analysis in all domains. You get the functionality of a wide-band vector signal analyzer, a spectrum analyzer and the unique trigger-capture-analyze capability of a Real-Time Spectrum Analyzer — all in a single package.
Revolutionary DPX Displays Transients as Short as 24 micros with 100% probability of intercept
DPX Spectrum Processing Provides an Intuitive Understanding of Time-varying RF Signals with Color Graded Displays Based on Frequency of Occurrence
Tektronix Exclusive 40 MHz and 110 MHz Frequency Mask Triggers (FMT) Offer Easy Event-based Capture of - Transient RF Signals by Triggering on any Change in the Frequency Domain
Power Trigger Provides High Resolution Trigger on Time Domain Events
2 External Triggers Provide Flexible Control of Triggering from ATE and Other System Equipment
All Signals in Up to 110 MHz Spans are Captured into Memory
Up to 1.7 s Acquisition Length at 110 MHz Bandwidth Provides Complete Analysis Over Time Without Making Multiple Acquisitions
6.2 GHz and 14 GHz Models Available
Extensive Time-correlated Multi-domain Displays Connect Problems in Time, Frequency, Phase and Amplitude for Quicker Understanding of Cause and Effect when Troubleshooting
All Functions are Easily Accessible via the Windows Interface. Use the Front Panel, Keyboard, Touch Screen or Mouse, Whatever you Prefer
Power Measurements and Signal Statistics Help You Characterize Components and Systems: ACLR, Multi-Carrier ACLR, Power vs. Time, CCDF
Advanced Measurement Suite (Opt. 20) - Pulse Measurements Including Rise Time, Pulse Width and Pulse-to-Pulse Phase Provide Deep Insight into Pulse Train Behavior
General Purpose Digital Modulation Analysis (Opt. 21) Provides Vector Signal Analyser Functionality
Frequency Range - 9 kHz to 14 GHz
Center Frequency Setting Resolution - 0.1 Hz
Span Accuracy - +/-0.3% (Auto mode)
Spectrum Processing Rate - >48,828/s
Minimum Signal Duration for 100% Probability of Detection (Max-hold On) - 31 micros (24 micros Opt. 110)
Input Attenuator Range - 0 dB to 75 dB, 5 dB step
Maximum Safe Input Level - Average Continuous (RF ATT =10 dB): +30 dBm