Product Description


  • DC 2500A, AC 2100A

  • 55mm dia., Bus Bar 65mm x 24mm

  • True RMS, Autorange, Diode test

  • Integrated Current Probe with analog output for Chart Recorder or Oscilloscope

  • 3¾ digit display with fast bar graph

  • 4000 counts of resolution

  • Max/Min/Hold & Continuity

  • Relative Measurement

  • Warranty: Two years

  • Price: $450.00 US dollars



SPECIFICATIONS: (23°C ± 5°C)
DC Current

RangeResolutionAccuracy (of rdg)Overload Protection
400A0.1A± 1.5% ± 3dgts3000 amps DC
0-2000A1A± 1.5% ± 3dgts3000 amps DC
2000-2500A1A± 2.0% ± 3dgts3000 amps DC


AC Current: (True RMS, Crest factor < 4)

Accuracy (of rdg)Overload Protection
RangeResolution50/60 Hz40Hz - 1kHz
400A0.1A± 1.5% ± 5dgts± 2.0% ± 5dgts3000 amps AC
0-1000A1A± 2.0% ± 5dgts± 2.5% ± 5dgts3000 amps AC
1000-2100A1A± 2.5% ± 5dgts± 3.0% ± 5dgts3000 amps AC


Analog Output Current:

RangeOutputAccuracyOverload Protection
0-400A1mV/A± 2.5% ± 0.5A600 volts AC
400A-2100A1mV/A± 2.5% ± 5A600 volts AC


DC Voltage: (Autorange & Manual. Overload protection 800VAC for all ranges)

RangeResolutionAccuracy (of rdg)Input Impedance
40mV0.1 mV± 1.5% ± 3dgts10MΩ
4V1 mV± 1.5% ± 3dgts5MΩ
40V10 mV± 1.5% ± 3dgts5MΩ
400V100 mV± 1.5% ± 3dgts5MΩ
600V1V± 1.5% ± 3dgts5MΩ


AC Voltage: (True RMS, Crest Factor < 4. Input impedance 5 MΩ)

AccuracyOverload Protection
RangeResolution50/60 Hz40Hz - 1kHz
400mV0.1mV--------1--------1--------1
4V1 mV± 1.5% ± 5dgts± 2.0% ± 5dgts800 volts AC
40V10 mV± 1.5% ± 5dgts± 2.0% ± 5dgts800 volts AC
400V100 mV± 1.5% ± 5dgts± 2.0% ± 5dgts800 volts AC
600V1V± 1.5% ± 5dgts± 2.0% ± 5dgts800 volts AC
1Although 400mV AC can be selected by the RANGE key, the Prova 2000 is not designed to measure AC millivolts. Consequently no accuracy is listed for the 400mV AC range. For accurate millivolt measurements, see: Multimeters


Resistance: (Autorange & Manual. Open Circuit Voltage ≤ 0.5V)

RangeResolutionAccuracyOverload Protection
400Ω0.1Ω± 1.5% ± 3dgts600 volts AC
4kΩ1Ω± 1.5% ± 3dgts600 volts AC
40kΩ10Ω± 1.5% ± 3dgts600 volts AC
400kΩ100Ω± 1.5% ± 3dgts600 volts AC
4MΩ1kΩ± 1.5% ± 3dgts600 volts AC
40MΩ10kΩ± 1.5% ± 3dgts600 volts AC


Continuity: (Overload protection 600VAC. Open circuit voltage 0.4V)

RangeResolutionAccuracyBeeping
40Ω-400Ω0.1Ω± 1.0% ± 2dgts< 40.0Ω


Diode Test:

RangeResolutionAccuracyOverload Protection
3V0.001V± 2.5% ± 5dgts600 volts AC


Frequency: (OL protection 600VAC. Sensitivity selected with RANGE button)

RangeResolutionAccuracySensitivity
100Hz-1000kHz0.01Hz - 100Hz± 0.5% ± 2dgts10mV/100mV/1V


General specifications:

Applicable standardsEN 61010-2-032, CAT III 600V, Pollution Degree 2
Conductor sizeCable diameter 55mm approximately (2.2")
Bus Bar 65mm(D) x 24mm(W), (2.6" x 0.9")
Display3¾ digit LCD with 40 segment bar graph
Operating temperature4°C to 50°C
Dimensions271(L) x 112(W) x 46(H)mm, (10.7" x 4.4" x 1.8")
Weight647g (batteries included), (1½ lb approx.)
Accessories includedUser's Manual, 9V battery, Carrying Bag