Sorry, the search criteria can not be empty
Search

ACR SmartReader 9 Three Channel Pulse Data Logger by Test Equipment Depot

  • Item Condition:
  • Brand:
  • Model#:
  • Location:
  • Price:
Test Equipment Depot
781.665.1400


Contact the seller Add to Inquiry Cart

Product Description

  • Three Channels

  • Count digital pulses or dry switch contact closures (i.e. on/off, open/close)

  • User selectable frequency ranges

  • 8-bit resolution

  • 10-year battery life

  • Remote access via modem or Ethernet

  • Network capable (connect up to 10 data loggers)

  • User configurable

The SmartReader 9 is a versatile data logger designed for counting and recording digital pulses or switch contact closures. It has two input channels, each with three selectable frequency ranges. Data can be displayed in custom engineering units using the simple equation editor of ACR's TrendReader® Standard software. It also has one internal channel for recording ambient temperature.
SmartReader 9 Specifications
No. of Channels
Three
  • One for Ambient Temperature

  • Two for externally-generated pulse signals or dry switch contact closures

Voltage Inputs
Input Type: Active logic signals
Input Voltage: Low = 0 to 0.5 volts DC
High = 4.5 to 24 volts DC
Ranges
32 pulses/second
64 pulses/second
128 pulses/second
Clock Accuracy+/- 2 seconds per day
Sampling Methods1. Continuous (First-in, First-out)
2. Stop when full (Fill then stop)
Sampling RatesUser selectable rates from 8 seconds to once every 5 days
Operating Limits-40 to 70°C (-40 to 158°F) and 0 to 95% relative Humidity
Accuracy+/- 1% of full scale
Input Impedance750K ohms
Minimum Pulse Width4 milliseconds
Switch Contact Closure InputInput type: Uncommitted switch or relay contacts
Memory Size32 KB (32,767 readings)
Resolution8-bit
External ConnectorRemovable screw-type terminal strip with common (-) connection
General SpecificationsSize60 mm x 48 mm x 19 mm (2.4" x 1.9" x 0.7")
MountingMagnetic backing and locking eyelet
Case MaterialNoryl plastic
Power SourceBattery3.6 volt Lithium
Battery Life10 Years under normal use
Internal Temperature SensorTypeNTC thermistor (10,000 ohms @ 25°C [77°F])
Range-40 to 70°C (-40 to 158°F)
Accuracy+/- 0.2ºC over the range: 0 to 70ºC (+/- 0.3ºF over the range: 32 to 158ºF)
Resolution0.4ºC (0.7ºF) @ 25ºC; better than 1ºC (1.8ºF) between -25 and 70°C (-13º and 158ºF); better than 2.0ºC (3.6°F) between -40 and -25°C (-40ºF and -13ºF)


Item added to Inquiry Cart

Continue shopping Go to Inquiry Cart