ACR Conservation Logger Four-Channel Temperature, RH and 5V Input Data Logger by Test Equipment Depot

  • Item Condition:
  • Brand:
  • Model#:
  • Location:
  • Price:
Test Equipment Depot
781.665.1400


Contact the seller Add to Inquiry Cart

Product Description

  • Monitor and record temperature, RH and any parameter with a 0-5 VDC output

  • Visual alarm

  • 12-bit resolution

  • 5-year battery life

  • 128 KB memory (87,000 readings)

  • Fast sample rates (up to 25 samples per second)

  • Network capable

  • Remote access via modem or Ethernet. User configurable

The Conservation Logger is a self-contained temperature and relative humidity logger with two external channels for use with a variety of sensors. It is equipped with an LED light that will alert the user if measurements fall above or below user set limits.  With 12-bit resolution, user selectable sample rates, 50 year battery life and an LED light for visual alarming, it is the ideal solution for museums , libraries, and archives where temperature humidity and light are important factors to the preservation and conservation of precious, valuable items.
Conservation Logger Specifications
No. of Channels
Four
  • One for Temperature

  • One for RH Sensor

  • Two external Sensors for any type with a 0-5VDC output

Sampling Methods1. Continuous (First-in, First-out)
2. Stop when full (Fill then stop)
Sampling RatesUser selectable rates from 25 per second to once every 8 hours
BP-101 Battery Pack or PS-201 Power supply is required for sample rates faster then 8 seconds
Clock Accuracy+/- 2 seconds per day
Memory Size128 KB (87,000 readings)
Temperature SensorTypeNTC Thermistor
Range-40 to 70°C (-40 to 158°F)
Accuracy+/- 0.2°C over the range 0 to 70°C (+/- 0.3°F over the range of 32 to 158°F)
Resolution0.03ºC at 25°C (0.05ºF at 77°F); better than 0.07ºC (0.12°F) between -25 and 70°C (-13 and 158°F); better than 0.13ºC (0.23°F) between -40 and -25°C (-40 and -13°F)
RH SensorTypeCapacitive thin polymer film
Range-0 to 95% RH
Accuracy+/- 3% RH from 10 to 90% (-20 to 40ºC [-4 to 104ºF])
ResolutionBetter than 0.04% RH between 25 and 60% RH at 25ºC (77ºF)
External Sensor RangeRangeAny two sensors with a 0-5 VDC output
Operating Limits-40 to 70°C (-40 to 158°F)
Resolution12-bit
Power SourceBattery3.6 volt Lithium, 1 Amp-Hour
Power Consumptions5 years under normal use (factory replaceable)
Battery Life10 Years under normal use
General SpecificationsSize107 mm x 74 mm x 22 mm (4.2" x 2.9" x 0.9")
Case MaterialNoryl plastic
MountingMagnetic backing and locking eyelet
CertificationCertified to CE standard EN50082-1: 1992 (European Generic Immunity) covering ESD, RFI, and EFT/B
Meets CE Standards EN55011 Class B: 1991 (European Radiated Emissions) and CISPR Class B: 1991 (International Radiated Emissions)